Unit Converter

dBm, watts, dBµV, volts, V/m, power density, frequency and wavelength. Type in any box.

For estimating and education only. Results come from the simplified models described below, are provided as is with no warranty, and are not a substitute for engineering analysis, simulation or measurement. Check them before relying on them in a design, purchase or safety decision. See the terms of use.

Equations

\mathrm{dBm} = 10\log_{10}\frac{P}{1\ \mathrm{mW}}, \qquad \mathrm{dBW} = \mathrm{dBm} - 30
P = \frac{V^2}{Z}, \qquad \mathrm{dB}\mu\mathrm{V} = 20\log_{10}\frac{V}{1\ \mu\mathrm{V}} = \mathrm{dBm} + 90 + 10\log_{10} Z
S = \frac{E^2}{\eta_0}, \qquad \eta_0 = 376.730\ \Omega
1\ \mathrm{W/m^2} = 0.1\ \mathrm{mW/cm^2}
\lambda = \frac{c}{f}, \qquad \lambda_\mathrm{dielectric} = \frac{c}{f\sqrt{\varepsilon_r}}

Variables

SymbolMeaningUnit
PPowerW
VRMS voltage across the loadV
ZLoad impedanceΩ
EElectric field strength (rms)V/m
SPower density, far-field plane waveW/m²
\eta_0Impedance of free spaceΩ

Worked example

InputValue
Power30 dBm

30 dBm is 1 W, 0 dBW, and 7.07 V rms across 50 Ω (136.99 dBµV). Every +3 dB roughly doubles the power; every +10 dB is ten times.

Load this example in the calculator

Validity

  • Voltages are RMS. Peak voltage for a sine wave is √2 times larger.
  • The field-strength relation holds in the far field of the antenna, in free space.
  • dBµV depends on the impedance; the tool defaults to 50 Ω.

Sources

  1. ITU-R Recommendation V.574, Use of the decibel and the neper in telecommunications.
  2. CODATA 2018 recommended values (speed of light, impedance of free space).

Need a design built around the numbers?